Test number: | 5064 |
Cable type: | CFBUS.PUR.049 |
Cable type: | Bus cables |
Bend radius: | 75mm (factor 10.3 x d) |
Service life: | 17 million strokes |
A machine's display is the control centre where every machine tool function is adjusted and checked. To allow rapid data transmission in real time, these control units often have Ethernet cables. For large systems in particular, it has proven effective to make this control unit moveable, even linearly moveable. A reliable cable is now required to properly map the recurring movement.
This test assessed the CFBUS.PUR.049 bus cable service life. After 14 months and 17,495,094 double strokes, we terminated the test. The cable was still in perfect condition, which is elementary for a control panel.